Uploaded the .BIN files into SMPPTS, get an error during RECEIVE as follows.
GIM57701T ** AN I/O ERROR OCCURRED DURING READ PROCESSING FOR THE SMPPTFIN DATA SET.
GIM27401T ** I/O ERROR - ,CAGENAPM, RECEIVE ,639C,D,SMPPTFIN,GET ,WRNG.LEN.RECORD...
Release : 8.6
Component : Gen INSTALL
The SMPPTFIN DD needs to be sequential (PO) in format.
If the input for the SMPPTFIN DD resides in a PDS , there are a couple of options
1. Concatenate all the PDS members in the SMPPTFIN DD as below:
//SMPPTFIN DD DISP=SHR,DSN=S9214.PDSM.R77.APARS(LUXXXXXX)
// DD DISP=SHR,DSN=S9214.PDSM.R77.APARS(LUXXXXXX)
// DD DISP=SHR,DSN=S9214.PDSM.R77.APARS(LUXXXXXX)
2. copy all the PDS members into 1 sequential file.
Alternate product KB article was used in addition to create this document:
CA PDSMAN GIM57701T ** AN I/O ERROR OCCURRED DURING READ PROCESSING FOR THE SMPPTFIN DATA SET.GIM27401T ** I/O ERROR - ,S9214R24,RECEIVE ,73AD,D,SMPPTFIN,GET ,WRNG.LEN.RECORD,00000200000000,QSAM