"Detected incompatible model mask configuration" error after upgrade from Spectrum 10.4 to 10.4.2
search cancel

"Detected incompatible model mask configuration" error after upgrade from Spectrum 10.4 to 10.4.2

book

Article ID: 199947

calendar_today

Updated On:

Products

CA Spectrum

Issue/Introduction

After performing a Distributed Install to upgrade Spectrum 10.4.0 to 10.4.2, user is seeing a ""Detected  incompatible model mask configuration" error when starting the SpectroSERVER process:

 

Environment

Release : 20.2

Component : Spectrum Core / SpectroSERVER

Cause

For this particular issue, the user had set the "ss_install=no" in the Host Installation Information (HII) file.

Resolution

When upgrading the SpectroSERVER system using the Distributed Installation method, ensure you have set "ss_install=yes" in the HII file.

Additional Information

Please reference the "HII File Parameters" section of the documentation for more information.