The Baseboard Management Controller (BMC) is a chip on the S500, S400, and S200 series motherboards that supports the Intelligent Platform Management Interface (IPMI) specification.
The BMC controls and monitors hardware-related information such as temperatures, voltages, fan speeds, etc.
The ability to upgrade the BMC firmware has been added to hardware diagnostics version 3.1.2.1 or later for S-Series appliances.
To Download the Hardware Diagnostic images:
The hardware diagnostics image is specific to the model of the appliance (S200, S400, S500)
Please select an the appropriate download link from the table below:
S-Series model |
HW diagnostics version |
MD5 |
Download Link |
S200 |
3.1.5.1 |
6b9bd6cb68e1d169cff2ba4cbf7b9c66 |
|
S400 |
3.1.6.0 |
fa46a7dc4a2a2fa29b171463b9a15fc4 |
|
S500 |
3.1.4.1 |
9404621ede6e9626038d5694b952f044 |
The following table indicates which appliances have the ability to upgrade the hardware diagnostics and BMC firmware:
Appliance | Model | Hardware Diagnostics Supported Upgrade Method |
---|---|---|
Advanced Secure Gateway | ASG-S500 ASG-S400 ASG-S200 |
Hardware diagnostics are upgraded from the CLI in the same manner as the Edge SWG (ProxySG) appliances. Hardware Diagnostic Install Instructions |
Content Analysis |
CAS-S500 CAS-S400 CAS-S200 |
Hardware diagnostics are upgraded from within the Management Console. For details on installing hardware diagnostics, refer to the Content Analysis system images install instructions |
Management Center |
MC-S400 |
Hardware diagnostics are upgraded from the CLI. |
Edge SWG (ProxySG) |
SG-S500 SG-S400 SG-S200 |
Hardware diagnostics are upgraded from the CLI. Hardware Diagnostic Install Instructions |
Upgrading the BMC firmware with the hardware diagnostics upgrade bmc command takes either 3 or 30 minutes to complete depending on the S-Series model:
Model | BMC Upgrade Time |
---|---|
S500 | 3 minutes |
S400 | 3 minutes |
S200 | 30 minutes |
NOTE: The BMC firmware is embedded in hardware diagnostics version 3.1.2.1 or later, i.e. there is no separate BMC firmware to download.
NOTE: Any hardware diagnostic test or show commands, e.g. "test disk", "test memory", "show environment" etc, should be issued BEFORE upgrading the BMC firmware.
Immediately after upgrading the BMC firmware, it is necessary to exit the diagnostics and cold power cycle the appliance.
REQUIREMENTS:
Upgrading the hardware diagnostics and BMC firmware requires the following:
OVERVIEW OF PROCESS:
For additional information on hardware diagnostics, refer to the Hardware Diagnostics" section in the S-Series Maintenance and Upgrade Guide.