GIM30206E for SMPE APPLY CHECK for RO64305 and RO66636.
search cancel

GIM30206E for SMPE APPLY CHECK for RO64305 and RO66636.

book

Article ID: 14452

calendar_today

Updated On:

Products

Top Secret Top Secret - LDAP

Issue/Introduction

How to resolve a GIM30206E when doing an APPLY CHECK for RO64305 and RO66636.

Getting a GIM30206E when doing an APPLY CHECK for RO64305 and RO66636:

APPLY CHECK          SELECT   (                    RO64305                    RO66636                   )          RETRY(YES)          GROUPEXTEND                 . 

GIM30206E ** APPLY PROCESSING FAILED FOR SYSMOD RO64305. HOLD REASON IDS WERE NOT RESOLVED.
GIM35965I SYSTEM HOLD ACTION ORIGINATED BY SYSMOD RO64305 WAS NOT RESOLVED.
GIM30206E ** APPLY PROCESSING FAILED FOR SYSMOD RO66636. HOLD REASON IDS WERE NOT RESOLVED.
GIM35965I SYSTEM HOLD DYNACT ORIGINATED BY SYSMOD RO66636 WAS NOT RESOLVED.
GIM24801S ** NO SYSMODS SATISFIED THE OPERANDS SPECIFIED ON THE APPLY COMMAND.
GIM20501I APPLY PROCESSING IS COMPLETE. THE HIGHEST RETURN CODE WAS 12.
GIM20502I SMP/E PROCESSING IS COMPLETE. THE HIGHEST RETURN CODE WAS 12.
SMP/E IS AT LEVEL 35.50.1PAGE 0001 - NOW SET TO TARGET ZONE TZONE2 DATE 05/18/17 TIME 16:52:44 SMP/E 35.50 SMPRPT OUTPUT APPLY CHECK SELECT ( RO64305 RO66636 ) RETRY(YES) GROUPEXTEND

Environment

Release:
Component: TSSMVS

Resolution

BYPASS(HOLDSYSTEM,HOLDERROR,HOLDUSER)

can be added to the APPLYCHECK control statement to get around the error.