How to resolve a GIM30206E when doing an APPLY CHECK for RO64305 and RO66636.
Getting a GIM30206E when doing an APPLY CHECK for RO64305 and RO66636:
APPLY CHECK SELECT ( RO64305 RO66636 ) RETRY(YES) GROUPEXTEND .
GIM30206E ** APPLY PROCESSING FAILED FOR SYSMOD RO64305. HOLD REASON IDS WERE NOT RESOLVED.
GIM35965I SYSTEM HOLD ACTION ORIGINATED BY SYSMOD RO64305 WAS NOT RESOLVED.
GIM30206E ** APPLY PROCESSING FAILED FOR SYSMOD RO66636. HOLD REASON IDS WERE NOT RESOLVED.
GIM35965I SYSTEM HOLD DYNACT ORIGINATED BY SYSMOD RO66636 WAS NOT RESOLVED.
GIM24801S ** NO SYSMODS SATISFIED THE OPERANDS SPECIFIED ON THE APPLY COMMAND.
GIM20501I APPLY PROCESSING IS COMPLETE. THE HIGHEST RETURN CODE WAS 12.
GIM20502I SMP/E PROCESSING IS COMPLETE. THE HIGHEST RETURN CODE WAS 12.
SMP/E IS AT LEVEL 35.50.1PAGE 0001 - NOW SET TO TARGET ZONE TZONE2 DATE 05/18/17 TIME 16:52:44 SMP/E 35.50 SMPRPT OUTPUT APPLY CHECK SELECT ( RO64305 RO66636 ) RETRY(YES) GROUPEXTEND
BYPASS(HOLDSYSTEM,HOLDERROR,HOLDUSER)
can be added to the APPLYCHECK control statement to get around the error.