What action is required when message U11D-A100-3 occurs in CA Workload Automation Restart Option for z/OS Schedulers?
search cancel

What action is required when message U11D-A100-3 occurs in CA Workload Automation Restart Option for z/OS Schedulers?

book

Article ID: 14375

calendar_today

Updated On:

Products

CA-11

Issue/Introduction



What action is required when message U11D-A100-3 occurs in CA Workload Automation Restart Option for z/OS Schedulers? 

Environment

Release: ELEVEN00200-11-Workload Automation-Restart Option-for Z/OS Schedulers
Component:

Resolution

U11D-A100-3 DATABASE AREA CONTAINING AUDIT TABLE IS FULL indicates that auditing has been requested, and no space is available in the database area that contains the audit table. The audit table resides in the JEHF database area. Auditing of the database element is ignored. Message U11D-A100-4 or U11D-A100-5 is issued, and an action is taken based on the value of the AUDITSUP configuration file parameter. 

 

Resolve the database full condition by performing one of the following actions:  

 

n --Run the maintenance task to purge aged audit information from the database.                                                               

--Reduce the number of days that the database retains auditing information by changing the AUDITAGE configuration file parameter and running the maintenance task to purge aged audit information from the database.     

--Expand the size of the JEHF database area.

--Run Datacom/AD DBUTLTY Defrag if IXX area is full.   

   

 As always, please contact CA Technologies support for CA Workload Restart Option for z/OS Scheduler if you have further questions.