Issue/Introduction



Are EAV DASD files fully supported by IDMS for database files in release 18.5 and 19.0?

Environment

Release: IDADSO00100-18.5-ADS-for CA-IDMS
Component:

Resolution

Yes.
For 18.5 there are two required PTFs:

RO60748 - 
PROBLEM DESCRIPTION: 
A S113-44 abend will occur during the open of an CA IDMS database 
file which is located on an Extended Address Volume beyond the 
65,520 cylinder address range. 

and RO60751 - 
PROBLEM DESCRIPTION: 
Dynamically allocated work files requested by a CA IDMS utility 
are not allocated above the 65,520 cylinder range on an EAV 
volume. 


  For 19.0 there are no PTFs required