Using the Hyperbuf ISPF panel interface to show the status of Hyperbuf in the system.
Using the Hyperbuf ISPF panel interface to show the status of Hyperbuf in the system. The display always shows the status an INACTIVE even though we have started Hyperbuf.
Environment
z/OS CA Hyperbuf 11.5 and above
Resolution
If you are looking at the ISPF panels and it shows INACTIVE and tiy have used the batch job to start Hyperbuf and it shows active, then you are not using the same load libraries for your ISPF session that you are using for the batch startup.
From the ISPF command line you can issue the following command: TSO ISRDDN
This will show you all the libraries allocated to your session.
Once you correct the library allocations all will be as expected.