Issue/Introduction
When applying CA-DB2 maintenance to the CDBALOAD library, do the Xmanager, and IDB2's PC and DC started tasks need to be stopped?
Environment
Release: Component: CIDB
Resolution
When applying maintenance to the CA DB2 Tools' executing libraries, you will need to stop the Xmanager, and IDB2's PC and DC started tasks.
Per maintenance Holddata: ******************************************************************************************************* Please do not apply maintenance to the Xmanager runtime libraries with Xmanager active as it may result in a discrepancy between dynamically loaded components and statically loaded components. This may result in unpredictable behavior with CA-DB2 tools and/or may compromise the operating system/DB2 including possible failures. **********************************************************************************************************