Juniper devices missing from group asset chassis report in CABI 4.3
book
Article ID: 93092
calendar_today
Updated On:
Products
CA Spectrum
Issue/Introduction
When running the Group Based Asset Chassis report in Spectrum Report Manager in CABI 4.3 Juniper and other non-cisco devices are missing
Environment
Release: Spectrum 10.2.3 integrated with BOXI Component: SPCRPT
Cause
The query that gets executed is configured to not display physical_class of 0 devices.
BIAR file contained a Chassis report that had the wrong query. This query was preventing the Juniper devices from displaying in the report. The report is configured to display physical_class from the chassis of 3 or 9. Juniper devices get a 0 because they do not support the entity mib.
Resolution
The Spectrum 10.2.3 BIAR file contains the right report which shows physical_class of 0 as well as 3 and 9.
Download a default 10.2.3 BIAR file that is attached to this KB.
Place the file in the $SPECROOT/Install-Tools/SRM-Tools/BIAR directory.
Move the rest of the *.biar files out leaving only the repmgr-core.biar file from this KB.
Navigate to the Spectrum OneClick webpage -> Administration -> report manager -> Manage Business Objects Content
Click "Update Content"
Once complete, report will function as originally designed.