Issue/Introduction
Customers using sFlow on NFA 9.3.8 may notice that the AS Numbers being reported for an interface are bogus.
<Please see attached file for image>

Environment
NFA 9.3.8
Windows 2012
Cause
NFA is not looking at the proper sFlow fields when reporting AS numbers.
Resolution
- Upgrade to NFA 9.3.8.
- Downloading Cumulative Patch: https://ftp.broadcom.com/user/downloads/pub/netqos/product_patches/NFA/9.3.8/NFA_9.3.8_CP_001.zip
- Extract the files and follow the included readme to carefully and properly apply the patch.
- Confirm that NFA interfaces are now reporting sFlow AS Numbers properly.