Creating a Load module from a program is giving the following error:
(CREATE MODULE mmmmm FROM PROGRAM ppppp)
1-IDADMODP04E - Load module facility unavailable to CA-IDEAL 1.0 programs,
=> CREATE MODULE mmmmm FROM PROGRAM ppppp
The error was due to program ppppp being invalid or not recognized as an IDEAL program object.
Check program ppppp for validity.
Program ppppp must be a an Ideal program Object compiled and pertaining to a VLS Object library.
If it does not then the CREATE module will fail with that IDADMODP04E message.
From CA IDEAL for CA Datacom Message Reference Guide Version 14.0:
IDADMODP04 - Load module facility unavailable to Ideal 1.0 programs
Reason: The user tried to use the load module facility on a program compiled under CA Ideal 1.0.
Action: Recompile under a current release (later than 1.0) and CREATE (or IDENTIFY) the program (after transport if necessary).