I've reloaded and double checked my parms thus far. However the standard install job fails -- IPC4RECD. It should be noted that the user doesn't control the DCB information for 'dsn name' and Broadcom has instructed SMP/E to define these temp datasets as (NEW,DELETE,DELETE). This appears to be a defect in the install process.
IEBCOPY MESSAGES AND CONTROL STATEMENTS PAGE 1
IEB1135I IEBCOPY FMID HDZ2210 SERVICE LEVEL UA83177 DATED 20161026 DFSMS 02.02.00 z/OS 02.02.00 HBB77A0 CPU 2828
IEB1035I IPC4RECD RCVBD 15:04:36 FRI 08 DEC 2017 PARM=''
COPY OUTDD=SMPTLIB,INDD=SMP00001 SMPTLIB - 2 CAVQF10
S M=((CAVQF10A,,R),(CAVQF10D,,R),(CAVQF10P,,R)) CAVQF10
IEB1013I COPYING FROM PDSE INDD=SMP00001 VOL=volser DSN='dsn name'
IEB1014I TO PDSE OUTDD=SMPTLIB VOL=volser DSN='dsn name '
IGW01513T RECFM INCOMPATIBLE -- INPUT RECFM = VB OUTPUT RECFM = FB
IGW01550I 0 OF 3 SPECIFIED MEMBERS WERE COPIED
IEB1130E A TERMINATING MESSAGE FROM FAMS PROCESSING APPEARS ABOVE -- DIAGNOSTIC INFORMATION IS X'28060000'
IEB151I JOB HAS TERMINATED WITH ERROR(S)
IEB147I END OF JOB - 8 WAS HIGHEST SEVERITY CODE
and
IEBCOPY MESSAGES AND CONTROL STATEMENTS PAGE 1
IEB1135I IEBCOPY FMID HDZ2210 SERVICE LEVEL UA83177 DATED 20161026 DFSMS 02.02.00 z/OS 02.02.00 HBB77A0 CPU 2828
IEB1035I IPC4RECD RCVBD 15:04:37 FRI 08 DEC 2017 PARM='CMWA=256K,SPCLCMOD'
COPYMOD OUTDD=SMPTLIB,INDD=SMP00001 SMPTLIB - 2 CAVQF15
S M=((ICVAANF,,R),(ICVAL,,R),(ICVAS,,R),(ICVAVAC,,R),(ICVAVRV,,R)) CAVQF15
S M=((ICVBACL,,R),(ICVBG,,R),(ICVBGUUC,,R),(ICVBP,,R)) CAVQF15
S M=((ICVBPDDC,,R),(ICVBPLLC,,R),(ICVBPWWC,,R),(ICVBS,,R)) CAVQF15
<snip>
S M=((VLTSRM65,,R),(VLTSWM65,,R)) CAVQF15
IEB1013I COPYING FROM PDSE INDD=SMP00001 VOL=volser DSN='dsn name'
IEB1014I TO PDSE OUTDD=SMPTLIB VOL=volser DSN='dsn name'
IGW01513T RECFM INCOMPATIBLE -- INPUT RECFM = U OUTPUT RECFM = FB
IGW01550I 0 OF 111 SPECIFIED MEMBERS WERE COPIED
IEB1130E A TERMINATING MESSAGE FROM FAMS PROCESSING APPEARS ABOVE -- DIAGNOSTIC INFORMATION IS X'28060000'
IEB151I JOB HAS TERMINATED WITH ERROR(S)
IEB147I END OF JOB - 8 WAS HIGHEST SEVERITY CODE
Other temp datasets function properly.
IEBCOPY MESSAGES AND CONTROL STATEMENTS PAGE 1
IEB1135I IEBCOPY FMID HDZ2210 SERVICE LEVEL UA83177 DATED 20161026 DFSMS 02.02.00 z/OS 02.02.00 HBB77A0 CPU 2828
IEB1035I IPC4RECD RCVBD 15:04:36 FRI 08 DEC 2017 PARM=''
COPY OUTDD=SMPTLIB,INDD=SMP00001 SMPTLIB - 1 CAVQF15
S M=((VQ15CSD,,R),(VQ15CSDT,,R),(VQ15FCT,,R)) CAVQF15
IEB1013I COPYING FROM PDSE INDD=SMP00001 VOL=volser DSN='dsn name'
IEB1014I TO PDSE OUTDD=SMPTLIB VOL=volser DSN='dsn name'
IGW01551I MEMBER VQ15CSD HAS BEEN COPIED
IGW01551I MEMBER VQ15CSDT HAS BEEN COPIED
IGW01551I MEMBER VQ15FCT HAS BEEN COPIED
IGW01550I 3 OF 3 SPECIFIED MEMBERS WERE COPIED
IEB147I END OF JOB - 0 WAS HIGHEST SEVERITY CODE
Datacom
Using DATACLAS different than default.
Customer needs to add DATACLAS(DEFAULT) parameters to the space allocation statements to resolve a problem with the ACS system not allowing the additional data set allocations with the record format of U.
IGW01513T RECFM INCOMPATIBLE - INPUT RECFM = iii OUTPUT RECFM = ooo
Explanation
The record format (RECFM) of the output data set is not
compatible with the record format of the input data set. FAMS
cannot copy from either a fixed length record format to a
variable length record format or to the opposite. Additionally,
undefined record format data sets can only be copied to data
sets with that same record format.
In the message text:
iii
The record format of the input data set.
ooo
The record format of the output data set.
System action
The system ends processing of the current invocation.
Operator response
Invoke FAMS with compatible record format combination.
Programmer response
Correct the conflicting RECFM specification on the output data set.
Source
DFSMSdfp and File and Attribute Management Services (FAMS).
Routing code
11
Descriptor code
6