Error when trying to load UC_UPD.txt to upgrade initial data
search cancel

Error when trying to load UC_UPD.txt to upgrade initial data

book

Article ID: 90038

calendar_today

Updated On:

Products

CA Automic Workload Automation - Automation Engine

Issue/Introduction

Error when trying to load UC_UPD.txt to upgrade initial data

Environment

Release: AOATAM99000-9.0-Automic-One Automation Tools-Application Manager
Component:

Resolution

Symptoms

  • Error when trying to load UC_UPD.txt to upgrade the initial data.


Investigation

Data needed for analysis:

  • Logfile of the load Utility (Default location Utility/temp folder)

The following information can be found in the load utility logfile:

U0038247 Minor Version of the database ('056') is higher than the Minor Version of the program ('040'). Can't continue.


Cause

The error message "U0038247 Minor Version of the database ('056') is higher than the Minor Version of the program ('040'). Can't continue." states
that the file you are trying to load is from a different version than the load utility you have in use.

Before Serviepack 4 the following components need to be out of the same service pack:

  • Automation Engine
  • Initial Data
  • Userinterface
  • Callapi
  • Utility

For example:

Trying to load a service pack 4 initial data with a load utility version out of service pack 2 is not possible.
The Utility first has to be upgraded to a servicepack 4 version, before loading the initial data out of service pack 4


Resolution

  • Upgrade the Utility to the same version as the Initial data that you are trying to load
  • Restart the load Utility and load UC_UPD.txt