Issue/Introduction

Job fails in Informatica

Environment

Release: AUTOME99000-2.0-Automic-Oracle Retail MOM-Enterprise Edition
Component:

Resolution

Symptoms

Concurrent job fails in Informatica-

Jobs that are not allowed to run concurrently in Informatica will fail and display a message like this in the output file:

java.lang.RuntimeException: workflow start error: pmcmd> ERROR:

Workflow [RepFolder1:wf_for_tail[version CheckedOut]]: Could not

acquire the execute lock for Workflow [wf_for_tail] []. Please check

the Integration Service log for more information.

pmcmd> ERROR: Unknown command [ENDENDENDENDENDENDEND!!].


Resolution:

The Informatica agent does support execution of concurrent Informatica workflows.
 To allow concurrent execution, the according Informatica workflow has to be configured as concurrent in Informatica.