Issue/Introduction

pset failure

Environment

Release: AOATAM99000-8.0-Automic-One Automation Tools-Application Manager
Component:

Resolution

Detailed Description and Symptoms
If a jobplan starts a job with ACTIVATE_UC_OBJECT(...,PASS_VALUES) the variable which is turnover with :PSET is only available when the parent jobplan is NOT deactivated.
 
Solution

The following opportunities make sure that the variable will be available for the child jobs.

*) Set the option "automatically deactivate when finished" -> "Time delay" to 1 day in the register card attribute.

*) deactivate the option "Generate at runtime" in the called job.
*) use the command :wait xx after calling the job with ACTIVATE_UC_OBJECT(...,PASS_VALUES).

There is an own table to handle this situation in Version 9.00A. In this version the failure will not occur.