Endevor Move Processor getting a C1G0272E error moving an element to the next stage.
C1X0012I STEP CPYLOAD INVOKING PROGRAM BSTCOPY
C1X0010I STEP CPYLOAD PROGRAM BSTCOPY COMPLETED, RC=0012
C1G0129E STEP CPYLOAD RC (0012) EXCEEDS THE MAX RC (0004) FOR THE PROCESSOR STEP
C1X0511I COPY COMMAND # 1
C1X0511I COPY O=OUTDD,I=INDD
C1X0511I SELECT MEMBER=((MEMBER1A,,R))
C1G0272E THE INDD DD STATEMENT IS MISSING.
All support releases
.
The most likely cause for a missing DD statement in a processor is the INDD DD statement is defined in an IF/THEN/ELSE clause and the condition being checked is not being satisfied resulting in no INDD DD statement being defined in the step.
Review the processor for IF-THEN-ELSE statements in the BSTCOPY step.
Check the keyword used in the IF statement and the symbolic substitutions to ensure that all conditions are coded for.
The EN$TRITE trace can be used to help evaluate IF-THEN-ELSE statements.
For more information on how to set up an Endevor trace in Foreground