CA Automic Workload Automation - Automation Engine
Issue/Introduction
Error Message : U01001002 Invalid MEMSV handle.
Output-Scan with Report-Scan and more than 10 filter-criterias lead to wp-crash or "invalid memsv-handle", and the following information is written into the logs and a force trace is written ------------- 20151223/223031.772 - U01001002 Invalid MEMSV handle. 20151223/223031.772 - EXIT UCUREP RET: 0001001002 TIME: 0000,01677 RETTEXT=' ' blkcnt=0000000000' 20151223/223031.772 - U00003620 Routine 'JPEXEC_R' forces trace because of error. ..... -------------
Error Description: If an output-filter is defined with a report-scan containing of more than 10 filter criterias, this leads to a overwritten memory during execution, which causes either a crash or the error message "invalid memsv-handle"