PCK.AUTOMIC_SMOKE_WEB with action "Get website Smoke test" fails when using Windows authentication on IIS Web Server

book

Article ID: 88042

calendar_today

Updated On:

Products

CA Automic Workload Automation - Automation Engine

Issue/Introduction

Error Message :
Received status code 401
Server authentication failed!

When using PCK.AUTOMIC_SMOKE_WEB with the action "Get website Smoke test" on an IIS Web Server, receive "Server authenticaton failed!" error as shown below.

smoke-web-tool: PARAM: ignoreServerCert = NO 
smoke-web-tool: PARAM: proxyPort = [] 
smoke-web-tool: PARAM: url = http://vvnsupwin01
smoke-web-tool: PARAM: timeout = 10000 
smoke-web-tool: PARAM: proxyHost = [] 
smoke-web-tool: PARAM: loglevel = 
smoke-web-tool: PARAM: proxyUsername = [] 
smoke-web-tool: PARAM: username = vvnsupwin01\hht 
Making the GET request to http://vvnsupwin01/ ... 
Authentication username: vvnsupwin01\hht 
Received status code 401 
Server authentication failed!

 

Cause

Cause type:
Defect
Root Cause: SMOKE WEB action pack does not handle Windows authentication on IIS

Environment

OS Version: N/A

Resolution

Update to a fix version listed below or a newer version if available.

Fix Status: Released

Fix Version(s):
Package Smoke Web 1.0.2 - Available

Additional Information

Workaround :
N/A