Cancelling an Agent Group container creates forced trace with U0000001 NO DATA
search cancel

Cancelling an Agent Group container creates forced trace with U0000001 NO DATA

book

Article ID: 87898

calendar_today

Updated On:

Products

CA Automic Workload Automation - Automation Engine

Issue/Introduction

Error Message :
U0000001 NO DATA (end of file, invalid key, no message...)

Cancelling an Agent Group container sporadically leads to a forced trace in the temp directory of the Automation Engine.

Once the force trace has been generated, the above error message can be found.




 

Environment

Release: AUTWAB99000-11.0-Automic Workload Automation-Base Edition
Component:

Cause

Cause type:
Defect
Root Cause: A cancel of an agent group container sporadically leads to a forced trace in the temp directory of the Automation Engine.

Resolution

Update to a fix version listed below or a newer version if available.
 

Fix Status: Released

Fix Version(s):
Automation Engine 11.2.2 - Available
Automation Engine 11.1.3 - Available
Automation Engine 10.0.8 - Available

Additional Information

Workaround :
N/A