JSCH activates every 20 seconds after periodic turnaround time
search cancel

JSCH activates every 20 seconds after periodic turnaround time

book

Article ID: 87868

calendar_today

Updated On:

Products

CA Automic Workload Automation - Automation Engine

Issue/Introduction

Error Message :
N/A


In Automtation Engine 11.2.3, when you add a UserDefined Metadata in a Schedule object (JSCH), it keeps activating/starting every 20 seconds after the periodic turnaround time.

<Please see attached file for image>

0EMb0000001Qxv5.png

The screen shot below shows the client has been stopped to stop JSCH from activating every 20 seconds.

<Please see attached file for image>

0EMb0000001Qxv0.png

To stop the activated JSCH from activating every 20 seconds, the Client must be stopped, then deactivate JSCH.

Note: This behavior does not exist in 11.2.4 or 12

 

Environment

Release: AUTWAB99000-11.0-Automic Workload Automation-Base Edition
Component:

Cause

Cause type:
Defect
Root Cause: N/A

Resolution

Update to a fix version listed below or a newer version if available.

Fix Status: Released

Fix Version(s):
Automation Engine 12.0.0 - Available
Automation Engine 11.2.4 - Available

Additional Information

Workaround :
Options:
1)  Upgrade Automation Engine to 11.2.4
2) Don't use UserDefined Metadata in JSCH in Automation Engine 11.2.3

 

Attachments

1558692817829000087868_sktwi1f5rjvs16luk.png get_app
1558692815775000087868_sktwi1f5rjvs16luj.png get_app