Variable in the process tab of a Workflow with ":PSET ¶m# = ' '" will be saved as an empty string when using Oracle
book
Article ID: 87792
calendar_today
Updated On:
Products
CA Automic Workload Automation - Automation Engine
Issue/Introduction
Error Message :
N/A
Setting a variable in the process tab of a Workflow when using an Oracle database with the following string:
:PSET ¶m# = ' '
results in the following outcome.
Actual
The variable will be saved as an empty string '' in the task of the Workflow.
Expected The variable result should be a blank and not an emtpy string.
Environment
Release: AUTWAB99000-11.0-Automic Workload Automation-Base Edition
Component:
Cause
Cause type:
Defect
Root Cause: A value of a variable consisting of several blanks will be saved as an empty string when using an Oracle database.
Resolution
Update to a fix version listed below.
Fix Status: Released
Fix Version(s):
Automation Engine 12.0 - Available
Automation Engine 11.2.3 - Available
Automation Engine 11.1.5 - Available
Additional Information
Workaround :
N/A
Feedback
thumb_up
Yes
thumb_down
No