RSET in Post-Process shows different behavior after a restart
book
Article ID: 87749
calendar_today
Updated On:
Products
CA Automic Workload Automation - Automation Engine
Issue/Introduction
Error Message : n/a
If a variable with value "" (null) within a Post-Process / Post-Script of a task is inherited with RSET, the restart will cause that a blank is read out in Postscript out of the variable.
Value in Post-Process before of restart: 2016-04-14 13:23:55 - U00020206 Variable '&VAR#' was stored with value ''. Value in Post-Process after restart: 2016-04-14 13:24:35 - U00020206 Variable '&VAR#' was stored with value ' '.
This field was added on 30/03/2017. This article has not been updated yet. Refer to the "Description" or "Workaround" sections for solution information.
Fix Status: Released
Fix Version(s): Automation.Engine 11.1.4 in AutomationEngine - already released Automation.Engine 11.2.2 in AutomationEngine - already released