File Transfer object not refreshed after Action-Restart

book

Article ID: 87587

calendar_today

Updated On:

Products

CA Automic Workload Automation - Automation Engine AUTOMIC WORKLOAD AUTOMATION

Issue/Introduction

Error Message :
N/A

The File transfer Object within a workflow (Agent TRANSFER Action) is not refreshed after Action-Restart.  It always shows the report of the first activation/execution.

Investigation
  • Use ECC Version 11.2.2
  • Create a test object
  • Execute this object once
  • Open the Monitor for this workflow
  • Restart the JOBF Task an open the report
Results:
  • If the workflow is automatically deactivated after a successfull execution and a task get's restarted there will be no update
  • If the workflow never deactivates (can be set in the attribute sheet) restart works and also the correct report gets loaded

Cause

Cause type:
Defect
Root Cause: If an already executed Filetransfer object gets restarted the UI doesn't refresh the state in the monitoring overview. Opening the report will show the versions of the first execution.

Environment

Release: AUTWAB99000-12.0-Automic Workload Automation-Base Edition
Component:

Resolution

This field was added on 30/03/2017. This article has not been updated yet. Refer to the "Description" or "Workaround" sections for solution information.

Fix Status: Released

Fix Version(s):
Automic Web Interface 12.0.0 - Available
Enterprise Control Center 11.2.3 - Available

Additional Information

Workaround :
N/A