File Transfer object not refreshed after Action-Restart
search cancel

File Transfer object not refreshed after Action-Restart

book

Article ID: 87587

calendar_today

Updated On:

Products

CA Automic Workload Automation - Automation Engine

Issue/Introduction

Error Message :
N/A

The File transfer Object within a workflow (Agent TRANSFER Action) is not refreshed after Action-Restart.  It always shows the report of the first activation/execution.

Investigation
  • Use ECC Version 11.2.2
  • Create a test object
  • Execute this object once
  • Open the Monitor for this workflow
  • Restart the JOBF Task an open the report
Results:
  • If the workflow is automatically deactivated after a successfull execution and a task get's restarted there will be no update
  • If the workflow never deactivates (can be set in the attribute sheet) restart works and also the correct report gets loaded

Environment

Release: AUTWAB99000-12.0-Automic Workload Automation-Base Edition
Component:

Cause

Cause type:
Defect
Root Cause: If an already executed Filetransfer object gets restarted the UI doesn't refresh the state in the monitoring overview. Opening the report will show the versions of the first execution.

Resolution

This field was added on 30/03/2017. This article has not been updated yet. Refer to the "Description" or "Workaround" sections for solution information.

Fix Status: Released

Fix Version(s):
Automic Web Interface 12.0.0 - Available
Enterprise Control Center 11.2.3 - Available

Additional Information

Workaround :
N/A