Error message occurs when executing EVNT type objects when user has authorization rights only on type EVNT
search cancel

Error message occurs when executing EVNT type objects when user has authorization rights only on type EVNT

book

Article ID: 87555

calendar_today

Updated On:

Products

CA Automic Workload Automation - Automation Engine

Issue/Introduction

Error Message :
U00004506 Access violation: User: 'EVNTTEST/NIX' Object: 'EVTI.UX.PRO2.TEST' Access: 'S' Reason: No right found in authorization group '1'.
...

The GET_STATISTIC_DETAIL script function executed in the !Process table of an Event, returns access denied error messages although the user has all needed rights on the EVNT.  

Error messages similar to these are displayed.
05 - 20160913/113921.083 - U00004506 Access violation: User: 'EVNTTEST/NIX' Object: 'EVTI.UX.PRO2.TEST' Access: 'S' Reason: No right found in authorization group '1'. 
05 - 20160913/113921.083 - U00004519 Access violation details: Used filter: '!EVNT/EVTI.UX.PRO2.TEST//////' . 
05 - 20160913/113921.099 - U00004506 Access violation: User: 'EVNTTEST/NIX' Object: 'EVTI.UX.PRO2.TEST' Access: 'P' Reason: No right found in authorization group '1'. 
05 - 20160913/113921.099 - U00004519 Access violation details: Used filter: '!EVNT/EVTI.UX.PRO2.TEST//////' . 
05 - 20160913/113921.114 - U00020999 Runtime error in object 'EVTI.UX.PRO2.TEST', line '00023': You do not have the necessary authorization for this instruction. 

Environment

Release: AUTWAB99000-11.0-Automic Workload Automation-Base Edition
Component:

Cause

Cause type:
Defect
Root Cause: The GET_STATISTIC_DETAIL script function executed in !Process tab of an Event, returned access denied although the user has all needed rights on EVNT.

Resolution

This field was added on 30/03/2017. This article has not been updated yet. Refer to the "Description" or "Workaround" sections for solution information.

Fix Status: Released

Fix Version(s):
Automation Engine 12.0.1 - Available
Automation Engine 11.2.3 - Available
Automation Engine 11.1.5 - Available

Additional Information

Workaround :
N/A