Mainframe Agent does not start and the following error message is displayed.
U2000105 Error when calling the function 'gss_acquire_cred' (Ret='458752', minor='1004').
(This is the typical U-code and message received in an OS/390 Agent log)
From Version 11 onward, this error message will have an additional "0" such as below:
U02000105 Error when calling the function 'gss_acquire_cred' (Ret='458752', minor='1004').
Agent MVS
An issue with the Agent "Transfer keys" appears on occasion. It occurs when the original authentication data (Company Key) information in the database does not match the authentication (Company Key) information for the Agent.
This problem can be caused by any of the following scenarios:
A) An Agent is started with the wrong Automation Engine system name in the Agent's "ini" file
B) A newly installed Agent is started with the same name as another Agent in a different directory
C) From a newly installed Agent\bin directory - the Agent is started with a new name, and subsequently started with a different name.
If the steps above do not work, then the following steps may also resolve this issue: