An object with a :WAIT between a :BEGINREAD and :ENDREAD block, gets stuck in "Generating" status
book
Article ID: 87528
calendar_today
Updated On:
Products
CA Automic Workload Automation - Automation Engine
Issue/Introduction
Error Message : N/A
An object with a :WAIT between a :BEGINREAD and :ENDREAD block will cause the object to get stuck in status of “generating” and does not show the read-mask.
If the option "generate at runtime" is set, the object will finish successfully.
Cause type: Defect Root Cause: Block-read not working if :WAIT is used between :BEGINREAD and :ENDREAD commands.
Resolution
This field was added on 30/03/2017. This article has not been updated yet. Refer to the "Description" or "Workaround" sections for solution information.
Fix Status: Released
Fix Version(s): Component(s): AE Server and Initialdata
Automation Engine 11.2.3 - Available
Additional Information
Workaround : Check the option “generate at runtime” for the job.