Restart Plus Run Time Module fails to delete existing datasets on EAV in production run mode: Uncatalogued instead

book

Article ID: 87451

calendar_today

Updated On:

Products

CA Automic Workload Automation - Automation Engine AUTOMIC WORKLOAD AUTOMATION

Issue/Introduction

Error Message :
n/a

The RestartPlus Run Time Module has the feature to delete existing datasets in production run, in case they exists already and the parameter disposition is set to “new” in the JCL.

The only affected datasets are those residing on “Extended Address Volumes” or EAV (The feature works as expected for datasets not residing on EAV).
The Run Time Module logs that the datasets were deleted, which is incorrect: They are only uncatalogued.

Jobs do not run as expected. Instead they fail with a JCL error.


 

Cause

Cause type:
Defect
Root Cause: Restart Plus Runtime Module fails to delete datasets residing on extended address volumes, which could not be located.

Environment

OS: MVS

Resolution

Update to a fix version listed below or a newer version if available.

Fix Status: Released

Fix Version(s):
Restart Plus 1.2P - available

Additional Information

Workaround :
Initially manually deleting the datasets.