CA Automic Workload Automation - Automation Engine
Issue/Introduction
Error Message : U04006578 RunID '' has not yet been generated. No data available for monitor.
Runtime of objects randomly display negative values in the Activity window / statistics / Process Monitoring view and the above error message is displayed upon trying to display the workflow monitor.
Example:
<Please see attached file for image>
Environment
OS Version: N/A
Cause
Cause type: Defect Root Cause: Tasks started with specific start time and start-type cause log-change, even if the task has already ended. In this case, the run-time of the task shows negative values.
Resolution
Update to a fix version listed below or a newer version if available.
Fix Status: Released
Fix Version(s): Component(s) : Automation Engine Server & Initial data
Automation Engine 12.1.0 - Available Automation Engine 12.0.3 - Available Automation Engine 11.2.6 - Available