This issue can not be reproduced. It will only occur when the Heap block on a system has been damaged and is dependant on the current operation of the Agent at that time.
Following are error messages and dump examples, which may help to identify the problem.
In the below example, the abend occurred after executing machine instruction 05EF (BRANCH AND LINK) in module UCXJM25 program §ST00020 at offset X'1FB8'.
14.03.53 STC48506 IEA995I SYMPTOM DUMP OUTPUT 111 111 USER COMPLETION CODE=4039 REASON CODE=00000000 111 TIME=14.03.50 SEQ=17003 CPU=0000 ASID=00C2 111 PSW AT TIME OF ERROR 078D1400 8A04C266 ILC 2 INTC 0D 111 NO ACTIVE MODULE FOUND 111 NAME=UNKNOWN 111 DATA AT PSW 0A04C260 - 00181610 0A0D58D0 D00498EC 111 GR 0: 00000000_84000000 1: 00000000_84000FC7 111 2: 00000000_17BB5FC8 3: 00000000_40404040 111 4: 00000000_0A040258 5: 00000000_0A04C266 111 6: 00000000_178103E0 7: 00000000_17BAC030 111 8: 00000000_17BB5FC8 9: 00000000_17BB5ADC 111 A: 00000000_17BB692F B: 00000000_8A04C188 111 C: 00000000_17BADBF0 D: 00000000_17BB8A18 111 E: 00000000_8A03F250 F: 7F4F1A00_00000000 111 END OF SYMPTOM DUMP
In the below example, the abend occurred after executing machine instruction 05EF (BRANCH AND LINK) in module UCXJM25 program §ST00011 at offset X'926'.14.03.54 STC48506 IEA995I SYMPTOM DUMP OUTPUT 117 117 USER COMPLETION CODE=4042 REASON CODE=00000001 117 TIME=14.03.53 SEQ=17016 CPU=0000 ASID=00C2 117 PSW AT TIME OF ERROR 078D1400 89FFD09E ILC 2 INTC 0D 117 NO ACTIVE MODULE FOUND 117 NAME=UNKNOWN 117 DATA AT PSW 09FFD098 - 00181610 0A0DA7F4 001C1811 117 GR 0: 00000000_84000000 1: 00000000_84000FCA 117 2: 00000000_00000001 3: 00000000_89F7C000 117 4: 00000000_17DD49C8 5: 00000000_00000001 117 6: 00000000_178103E0 7: 00000000_09FFD062 117 8: 00000000_80000000 9: 00000000_184FFCBC 117 A: 00000000_00000001 B: 00000000_89FFCFC0 117 C: 00000000_184FDBF0 D: 00000000_184FFAC0 117 E: 00000000_8A15628E F: 7F4F1A00_00000001 117 END OF SYMPTOM DUMP