Event Monitor abends with S0C4 RC 11
search cancel

Event Monitor abends with S0C4 RC 11

book

Article ID: 87183

calendar_today

Updated On:

Products

CA Automic Workload Automation - Automation Engine

Issue/Introduction

Error Message :
STC05390 IEF450I UC4EM UC4EM - ABEND=S0C4 U0000 REASON=00000011 631

The z/OS Event Monitor terminates after the start with S0C4 RC11

Environment

OS: Z/OS

Cause

Cause type:
Other
Root Cause: The VSAM to store the event statuses has been damaged and is inconsistent or other storage / volume related error persists.

Resolution

1. Recreate and reinitialize the VSAMs of the Event Monitor on all LPARS where the Event Monitor should be active according to the Step 04 or Step 08 of the Agent Install Guide:
 
2. Start the Event Monitor/s   

3. Check the scheduled z/OS Events and restart/reschedule them if necessary. Some Events could end in a passive/hanging state because of the initialization of the VSAMs.


Fix Status: No Fix

Fix Version(s):
N/A

Additional Information

Workaround :
N/A