Listener parameter is missing after Management Server update

book

Article ID: 86831

calendar_today

Updated On:

Products

CA Automic Sysload

Issue/Introduction

Affects Release version(s): 5

Error Message :
The parameter "Listener" is not kept after the upgrade

Patch level detected:Sysload Management Server 5.80
Product Version: Sysload 5.8.0

Description :After updating the Management Server v5.80 to v6.00, the "listener" parameter is not present in "sldmgts.ini"

Cause

Cause type:
Defect
Root Cause: N/A

Environment

OS: Windows

Resolution

Update to the fix version listed below or a newer version if available.

Fix Status: Released

Fix Version(s):
Component: Management Server
Version: Sysload 6.0.0
v6.00a

Additional Information

Workaround :
N/A