Unable to relaunch aborted jobs
search cancel

Unable to relaunch aborted jobs

book

Article ID: 86767

calendar_today

Updated On:

Products

CA Automic Dollar Universe

Issue/Introduction

Error Message :
The following pop-up error message appear

########
"L'objet référencé est introuvable".
########

or in english
########
referenced object not found
########

Patch level detected:Dollar Universe 6.0.00
Product Version: Dollar.Universe 6.0.0

Description :Unable to relaunch aborted jobs from Univiewer Console.

Environment

OS: All

Cause

Cause type:
Configuration
Root Cause: This message can appear when the concerned uproc has an incoherent value -1 in the severity field.

Resolution

You can solve this issue by modifying manually the severity field to 0 or using a command line to modify all uprocs:

uxupd upr upr=* geninf defsev=0000

Fix Status: No Fix
 

Additional Information

Workaround :
N/A