Unable to relaunch aborted jobs
book
Article ID: 86767
calendar_today
Updated On:
Products
CA Automic Dollar Universe
Issue/Introduction
Error Message :
The following pop-up error message appear
########
"L'objet référencé est introuvable".
########
or in english
########
referenced object not found
########
Patch level detected:Dollar Universe 6.0.00
Product Version: Dollar.Universe 6.0.0
Description :Unable to relaunch aborted jobs from Univiewer Console.
Cause
Cause type:
Configuration
Root Cause: This message can appear when the concerned uproc has an incoherent value -1 in the severity field.
Resolution
You can solve this issue by modifying manually the severity field to 0 or using a command line to modify all uprocs:
uxupd upr upr=* geninf defsev=0000
Fix Status: No Fix
Additional Information
Workaround :
N/A