Sysload Agent HyperV : Metrics with huge values cannot be saved on the history file
book
Article ID: 86657
calendar_today
Updated On:
Products
CA Automic Sysload
Issue/Introduction
Affects Release version(s): 5
Error Message : The value of the metrics Virtual Storage Device Overall '&' Virtual Storage Device Specific " are too big and could not be saved on the history file - Bytes written (B/s) Patch level detected:Sysload Agent for Hyper-V 5.80 Product Version: Sysload 5.8.0
Description :The metrics from the domains "Virtual Storage Device Overall" and "Virtual Storage Device Specific" cannot not be saved on the history file as they values are too big.
Cause
Cause type: Defect Root Cause: N/A
Environment
OS: Windows
Resolution
Update to the fix version listed below or a newer version if available.