Erroneus message in the Manager for zOS log

book

Article ID: 86299

calendar_today

Updated On:

Products

CA Automic Dollar Universe

Issue/Introduction

Error Message :
"connectUVMSgenericHA |Unable to connect to UVMS"

Patch level detected:Manager for MVS 6.3.41
Product Version: Dollar.Universe 6.3.41

Description :When using a Primary/Failover UVMS architecture and the UVMS node running is the Failover node, we can see erroneous error message logged every 30 seconds in the Manager for zOS log relatively to the primary node, this increase the log size quickly

Nothing appear when the UVMS primary node runs.

Cause

Cause type:
Defect
Root Cause: When the primary is down, the Manager for MVS should connect to the secondary but it is still trying to connect to the primary node despite the list in the node setting UVMS_REF is set to the correct order

Environment

OS: MVS

Resolution

Please check our compatibility Matrix before upgrading any product

Fix Status: Released

Fix Version(s):
Component: Manager.for.ZOS
Version: Dollar.Universe 6.4.41

Additional Information

Workaround :
N/A