Error Message :
No error appear

Patch level detected:Univiewer Console 6.2.00
Product Version: Dollar.Universe 6.2.0

Description :When upgrading a duas node 5.x having uprocs with dependencies on resources on other areas different than X, the uprocs when upgrading to 6.x remain in Event Wait indefinetely because the Supervisor of the concerned area is stopped.

Cause

Cause type:
Defect
Root Cause: The upgrade procedure that is done on the Univiewer Console did not parse correctly the uxstartup_gen file while upgrading to 6.xx

Environment

OS: All

Resolution

The upgrade kit 6.3.01 and the Univiewer Console 6.3.01 contain the correction that will allow to start automatically the Supervisor Engine on other areas as defined on the uxstartup_gen file of the 5.x nodes.

Fix Status: Released

Fix Version(s):
Component: Univiewer.Console
Version: Dollar.Universe 6.3.01

Additional Information

Workaround :