Manager MVS stc abend with "SOC4" code if the uproc submitted from Dollar Universe is using an invalid logon

book

Article ID: 86162

calendar_today

Updated On:

Products

CA Automic Dollar Universe

Issue/Introduction

Error Message :
In the $UNIVERS STC log:
##########################
13.39.26 STC39698 TSS7271E Job Submit/ACID Authorization Denied. ACID <S107832> Not Authorized for Your Use
...
13.43.33 STC39698 IEF450I $UNIVERS $UNIVERS - ABEND=S0C4 U0000 REASON=00000004 816
 816 TIME=13.43.33
 13.43.34 STC39698 ...JOB: $UNIVERS 001 MGR4ZOS MGR4ZOS -- CR: S0C4
 13.43.34 STC39698 IEF404I $UNIVERS - ENDED - TIME=13.43.34
...
TSS7271E Job Submit/ACID Authorization Denied. ACID <S107832> Not Authorized for Your Use
...
CEE3204S The system detected a protection exception (System Completion Code=0C4). 
From entry point _unilog at statement 496 at compile unit offset +0000071A at entry offset +0000071A at address 0FE13A4A.
##########################

Patch level detected:Manager for MVS 3.0.00
Product Version: Dollar.Universe 6.0.0

Description :Manager MVS stc abend with "SOC4" code if the uproc submitted from Dollar Universe is using an invalid logon

Cause

Cause type:
Defect
Root Cause: N/A

Environment

OS: MVS
Related configuration item(s): DUAS 6, UVMS

Resolution

Update to the fix version listed below or a newer version if available.

Fix Status: Released

Fix Version(s):
Component: Manager.for.ZOS
Version: Dollar.Universe 6.0.0

Additional Information

Workaround :
N/A