In the "New Run" dialog of the "Job Runs" of Univiewer Console, the Management Unit(MU) field does not display any list of available Management Units(MUs) when creating a manual launch.

book

Article ID: 86087

calendar_today

Updated On:

Products

CA Automic Dollar Universe

Issue/Introduction

Error Message :
No error message.

Patch level detected:Univiewer Console 4.0.00
Product Version: Dollar.Universe 6.0.0

Description :In the "New Run" dialog of the "Job Runs" of Univiewer Console, the Management Unit(MU) field does not display any list of available Management Units(MUs) when creating a manual launch.

Cause

Cause type:
Configuration
Root Cause: The profile of the user does not have sufficient rights on "MANAGEMENT_UNIT" when creating a launch manually.

Environment

OS: All
OS Version: ALL OS

Resolution

Based on the security file, the profile is missing some keyword specifically in "MANAGEMENT_UNIT".

~~~~~~~~~~~~~~~~~~~~~~~~~~
MANAGEMENT_UNIT=*
+
DISPLAY
~~~~~~~~~~~~~~~~~~~~~~~~~

The following keyword must be added.
#######################
USE_WITHIN_LAUNCH
#######################

- Ex:
#######################
MANAGEMENT_UNIT=*
+
DISPLAY
USE_WITHIN_LAUNCH
#######################

- Then, please relaunch Univiewer Console.

Fix Status: No Fix

Additional Information

Workaround :
N/A