Description :Dollar Universe upgrade from v5.6 to v6.x fails occasionally. After another attempt to upgrade, it completes with error message on UVC console.
Cause
Cause type: Configuration Root Cause: Some areas that should be started are not properly defined in values.xml to be started by default.
Environment
OS: All
Resolution
By default, only the Production(X) area is defined to start during the startup of the Dollar Universe. If for example, the default area to be started also includes another area (APP, INT or SIM), the following entries must be placed in values.xml
For Application area:
IOCDJBVSLANEXCCALSURALM
Or for Integration area:
IOCDJBVSLANEXCCALSURALM
Or for Simulation area:
IOCDJBVSLANEXCCALSURALM
After adding the corresponding information, stop and restart Dollar Universe.