Continuous Extraction is not stopped properly at shutdown.

book

Article ID: 86081

calendar_today

Updated On:

Products

CA Automic Dollar Universe

Issue/Introduction

Error Message :
There is no error message.

Patch level detected:Reporter 6.1
Product Version: Dollar.Universe 6.1.01

Description :Continuous Extraction is not stopped properly at shutdown.

Cause

Cause type:
Defect
Root Cause: Database connections opened by Continuous Extractions were not properly closed.

Environment

OS: All

Resolution

Update to the fix version listed below or a newer version if available.

Fix Status: Released

Fix Version(s):
Component: Reporter
Version: Dollar.Universe 6.2.21

Additional Information

Workaround :
N/A