AS400 open file error /QSYS.LIB/UCOMPANY.LIB/MGR.FILE/UNIESP.DSC.MBR

book

Article ID: 86014

calendar_today

Updated On:

Products

CA Automic Dollar Universe

Issue/Introduction

Affects Release version(s): 5

Error Message :
Error in the output window is 

====================================================================================
open file error /QSYS.LIB/UCOMPANY.LIB/MGR.FILE/UNIESP.DSC.MBR
====================================================================================

Patch level detected:Dollar Universe 5.1
Product Version: Dollar.Universe 5.1.1 FX24905

Description :Impossible to run a datafile reinitialization operation on a Dollar Universe installation 5.1.1 on AS 400, even if the fix FX24905 ist intalled.

Cause

Cause type:
Configuration
Root Cause: Following members are missing in MGR file of the Dollar Universe library

Environment

Release:
Component: ADLRUN

Resolution

1. Transfer via ftp the UNIESP per FTP on the AS400 host:

ftp
cd ORSYP
bin
put UNIESP

On AS 400 host, reate a library to restore the objects

crtlib UNIESP

Stop the DU company via the uxshutdown command:
Then, on the AS 400 restore this member:

RSTOBJ OBJ(*ALL) SAVLIB(UNIESP) DEV(*SAVF) SAVF(ORSYP/UNIESP)
T
he restored file (UNIESP.DSC, UNIESP.LOD, UNISOC.DSC, UNISOC.LOD) will be present in the UNIESP library.

2. Copy via the strpdm command the restored members in the mgr.file

UNIESP.DSC, UNIESP.LOD, UNISOC.DSC, UNISOC.LOD

Check that mgr file shows the following content

UXSETENV
UNIESP.DSC
UNIESP.LOD
UNISOC.DSC
UNISOC.LOD
U_FALI01
UXVERSION
=================================================================================

Now proceed with the required reinitialization. Reorganization with URGZSUBMIT CONFIRM(*YES) is also possible

Fix Status: No Fix
 

Additional Information

Workaround :
N/A