Description :When the history of a DUAS job (QPJOBLOG) exceeds 20000 lines, the log file DUAS can't be created : The temporay file used for copy is too small. Because of this, the uproc execution can be aborted (but not every time).
Environment
OS: IBM AS/400
Cause
Cause type: Defect Root Cause: N/A
Resolution
Dollar Universe 6.1.42 is a hotfix. Once installed, please set AS400_MAX_LOG variable to a adequate value
Using command line, example: UNISETVAR NAME('AS400_MAX_LOG') VARVALUE(33000)
or directly from Univiewer Console: AS400 node settings -> Advanced settings -> Maximum number of ilnes for an AS400 spool (0 meaning the Dollar Universe uses the system defaul value) : 33000