Issue/Introduction
Affects Release version(s): 3;4
Error Message : From the CLI output:
/uvms/univadm2-devl/app/bin/unisync NODE -host -login univa -pwd hidden -port 10788 -delete -override -type DU UniViewer Management Server environment loaded.
Connecting to reference UVMS /10788... Unable to extract node list: ServerException - readBinary: server closed connection (see log for more details) Synchronizing UVMS Node (hostnamel) NODE (DU)Configurations failed with RC=1.
FATAL ERROR - Return Code = 1
Patch level detected:Univiewer Management Server 4.0.00 The unisync command may fail when synchronizing information from a remote UVMS about Groups, users from LDAP serverĀ
Environment
OS: All OS Version: NA
Cause
Cause type: Other Root Cause: It is possible that the UVMS process was extremely busy at the time the command is executed.
Resolution
As a long term solution, starting from UVMS v4.x, a LDAP Group synchronization has been made available so that the UVMS can directly synchronize with the LDAP server of its Groups.