UVMS: unisync command may fail when synchronizing information about Groups, users from LDAP server.
search cancel

UVMS: unisync command may fail when synchronizing information about Groups, users from LDAP server.

book

Article ID: 85769

calendar_today

Updated On:

Products

CA Automic Dollar Universe

Issue/Introduction

Affects Release version(s): 3;4

Error Message :
From the CLI output:

/uvms/univadm2-devl/app/bin/unisync NODE -host -login univa -pwd hidden -port 10788 -delete -override -type DU
UniViewer Management Server environment loaded.

Connecting to reference UVMS /10788...
Unable to extract node list: ServerException - readBinary: server closed connection (see log for more details)
Synchronizing UVMS Node (hostnamel) NODE (DU)Configurations failed with RC=1.

FATAL ERROR - Return Code = 1

Patch level detected:Univiewer Management Server 4.0.00
The unisync command may fail when synchronizing information from a remote UVMS about Groups, users from LDAP serverĀ 

Environment

OS: All
OS Version: NA

Cause

Cause type:
Other
Root Cause: It is possible that the UVMS process was extremely busy at the time the command is executed.

Resolution

As a long term solution, starting from UVMS v4.x, a LDAP Group synchronization has been made available so that the UVMS can directly synchronize with the LDAP server of its Groups.

Fix Status: No Fix

Additional Information

Workaround :
As a workaround, restart UVMS.