The values of the metric physc of an entity Application are not correct (lower than expected)

book

Article ID: 85465

calendar_today

Updated On:

Products

CA Automic Sysload

Issue/Introduction

Affects Release version(s): 5

Error Message :
No error appear

Patch level detected:SP Analyst Agent for Unix 5.60
Product Version: Sysload 5.6.0

Description :The values of the metric physc of an entity Application are not correct ( lower than expected)

Cause

Cause type:
Defect
Root Cause: N/A

Environment

OS: IBM AIX

Resolution

The calculation rule for the metric %physc for a given process has been changed to:

PHYSC_proc = PHYSC_LPAR * %CPU_TOTAL_proc / %CPU_TOTAL_LPAR

instead of:

PHYSC_proc = PHYSC_LPAR * %CPU_TOTAL_proc / 100

Fix Status: Released

Fix Version(s):
Component: Agents
Version: Sysload 5.8.0

Additional Information

Workaround :
N/A