UVMS Cluster: Deployment of packages could fail if connected to the wrong member of the cluster
book
Article ID: 85436
calendar_today
Updated On:
Products
CA Automic Dollar Universe
Issue/Introduction
Error Message : On the uvserver.log the following error appears:
############################ |ERROR| package-1-worker-1 | com.orsyp.central.owlspackages.OwlsPackageBusiness | Error in uproc create com.orsyp.UniverseException: Error during file put ############################
Patch level detected:Univiewer Management Server 6.2.00 Product Version: Dollar.Universe 6.2.0
Description :On a cluster UVMS environment, If UVC is connected to the Member of UVMS cluster that does NOT store physically the Package to be deployed, the deployment will fail.
Cause
Cause type: By design Root Cause: This limitation was related to the cluster architecture.
Environment
OS: All Related configuration item(s): UVMS in cluster
Resolution
This problem has been fixed via the change of architecture of UVMS included starting on version 6.3.01 The active / active cluster does not exist anymore. Please check the Univiewer documentation for more details.