UVMS Cluster: Deployment of packages could fail if connected to the wrong member of the cluster

book

Article ID: 85436

calendar_today

Updated On:

Products

CA Automic Dollar Universe

Issue/Introduction

Error Message :
On the uvserver.log the following error appears:

############################
|ERROR| package-1-worker-1 | com.orsyp.central.owlspackages.OwlsPackageBusiness | Error in uproc create 
com.orsyp.UniverseException: Error during file put
############################

Patch level detected:Univiewer Management Server 6.2.00
Product Version: Dollar.Universe 6.2.0

Description :On a cluster UVMS environment, If UVC is connected to the Member of UVMS cluster that does NOT store physically the Package to be deployed, the deployment will fail.

Cause

Cause type:
By design
Root Cause: This limitation was related to the cluster architecture.

Environment

OS: All
Related configuration item(s): UVMS in cluster

Resolution

This problem has been fixed via the change of architecture of UVMS included starting on version 6.3.01
The active / active cluster does not exist anymore.
Please check the Univiewer documentation for more details.

Fix Status: Released

Fix Version(s):
Component: Univiewer.Management.Server
Version: Dollar.Universe 6.3.01

Additional Information

Workaround :
N/A