Cannot Stop successfully Dollar Universe on Windows via the command unistop
book
Article ID: 85227
calendar_today
Updated On:
Products
CA Automic Dollar Universe
Issue/Introduction
Error Message : The following errors may appear while trying to start after an unsuccessful stop of the company.
######################################################### | 2013-08-29 10:35:56 |ERROR|S|IO |pid=92584.93524| u_ouv_serv | failed in u_listen: (WinSock): Address already in use | 2013-08-29 10:35:56 |FATAL|S|IO |pid=92584.93524| u_io_srv_main | Error opening IO server S service: port number in use (already started?) #########################################################
Description :Some Dollar Universe processes may not stop successfully some components on Windows when stopping the Dollar Universe Instance via the command unistop. As a result, the ports may not be liberated so the next startup will fail starting the same components.
Environment
OS: Windows
Cause
Cause type: Defect Root Cause: N/A
Resolution
A new "force" option has been added to the unistop tool to force the termination of Dollar Universe processes and services for which control was lost.