Description :An uproc which launches an Axapta job stays indefinitely in running status. The same Axapta job is running fine when executed from Dynamic Axapta 2009 manually.
Environment
OS: Windows OS Version: All
Cause
Cause type: Configuration Root Cause: The Axapta job is creating a report (in PDF format for example) and
Resolution
In the Axapta job properties, instead of using a network mapped drive (P:\Axapta\Lotus_Notes_Reports for example) use a network path (\\aunsymf001\Public\Axapta \Lotus_Notes_Reports for example). After that, relaunch the uproc with DUAS. After a while, the uproc successfully ends.