DUAS 6 node not able to communicate with DUAS 5 node

book

Article ID: 85095

calendar_today

Updated On:

Products

CA Automic Dollar Universe

Issue/Introduction

Error Message :
|INFO |X|IO |pid=p.t| o_module_exc_cycle_emissi | Compatibility mode with v5 disabled: cannot handle article [EMN000000420000005SIDBATCH 00 W000000321X00U_U000000314000001 local U000000012000mae00000520131126230216A N000000420 000 00000000000000000000 ]


A Dollar Universe 6 node is not able to communicate with other Dollar Universe 5 nodes and print the above error message continously.

 

Cause

Cause type: Configuration
Root Cause: Compatibility mode with DU5 nodes is disabled by default on new node version 6.x installations

Environment

Dollar Universe 6.x

 

Resolution

Compatibility mode with DU5 nodes has to be enabled on the Dollar Universe 6 node.