C_PERIOD Object execution not successful because logical date set to '00000000'
search cancel

C_PERIOD Object execution not successful because logical date set to '00000000'

book

Article ID: 85091

calendar_today

Updated On:

Products

CA Automic Workload Automation - Automation Engine

Issue/Introduction

Error Message :
U00007026 '' activation is processed with the logical date '00000000'.

After Stopping a C_PERIOD Object and setting it to GO again, the first run is not successful. 

The logical date is always set to '00000000'', which leads to the above error message in the Activation Report.

 

Environment

OS Version: N/A

Cause

Cause type:
Defect
Root Cause: Wrong logical date in periodic object with option "GAP". Activate-period-job in jpexec_r sets the ldatum (and rdatum) fields of AKTX to EH_NextCheck. EH_NextCheck was set to NULL when the period was stopped.

Resolution

Update to a fix version listed below or a newer version if available.

Fix Status: Released

Fix Version(s):
Automation Engine 12.1.0 - Available
Automation Engine 12.0.2 - Available
Automation Engine 11.2.5 - Available

Additional Information

Workaround :
N/A