Archived components are displayed in Application Overview

book

Article ID: 85041

calendar_today

Updated On:

Products

CA Continuous Delivery Automation - Automation Engine

Issue/Introduction

Affects Release version(s): 7;8

Error Message :
N/A

In Application overview, archived components are shown.
 

<Please see attached file for image>

0EMb0000001Ult5.png

<Please see attached file for image>

0EMb0000001UltA.png

Cause

Cause type:
Defect
Root Cause: Archive Components are not properly filtered with the Auto Assign function (in Profile)

Environment

OS Version: N/A

Resolution

Update to a fix version listed below or a newer version if available.

To completely hide archived components follow the steps below: 
  1. Open the AWI Settings window, navigate to the Release Automation tab and disable Show archived items.
  2. For Administrators, open the web.config file and make sure this setting is set to false
<add key="References.ShowReferencedArchivedEntities" value="false"/>
 


Fix Status: Released

Fix Version(s):
Release Manager 7.0.2 - Available
Release Manager 8.0.0 - Available

Additional Information

Workaround :
N/A

Attachments

1558693552696000085041_sktwi1f5rjvs16m91.png get_app
1558693550655000085041_sktwi1f5rjvs16m90.png get_app