Jobs restarted using RESTART_UC_OBJECT don't indicate that they've been restarted.
book
Article ID: 84965
calendar_today
Updated On:
Products
CA Automic Workload Automation - Automation Engine
Issue/Introduction
Error Message : N/A
Jobs restarted with RESTART_UC_OBJECT don't indicate that they've been restarted. The initial job does not indicate that it was restarted but the restart indicates it was a restart. Neither the icon nor the database fields, ah_restart and eh_restart, are updated. If a job is restarted more than once, the initial job indicates that it was restarted, but the 2nd job does not indicate it was restarted.
If the Job is manually restarted via the User Interface (UI), then the db values and the icon are correctly updated. Also, in v9, if a restart is performed using the RESTART_UC_OBJECT function, the icon and the database indicate that the job has been restarted.
Cause type: Defect Root Cause: Jobs that are restarted using RESTART_UC_OBJECT don't indicate that they have been restarted. If the job is restarted manually it functions correctly.
Resolution
Update to a fix version listed below or a newer version if available.
Fix Status: Released
Fix Version(s): Automation Engine 11.2.5 - Available